Key Changes in Case 2-VF Treated with CPR & Automated External Defibrillation
  • CPR- 30 compressions to 2 ventilations
  • Compress over center of chest between nipples
  • Rotate compressor role every 2 minutes
  • Chest compression should be hard and fast: 100 compression per minute, allow for full chest recoil.
  • Apply AED patches and power-up during CPR / DO NOT INTERRUPT CPR TO APPLY PADS
  • One Shock only-After shock immediately resume CPR /Starting with compressions